Merge branch '14885-ciso-and-conda-packaging-pr'
[arvados.git] / doc / install / install-nodemanager.html.textile.liquid
index 9ee6722a07fa8b71be4b120e431b49f95635d881..defec2589e82a3f32266f39e500c54401ee57683 100644 (file)
@@ -11,7 +11,7 @@ SPDX-License-Identifier: CC-BY-SA-3.0
 
 Arvados Node Manager provides elastic computing for Arvados and SLURM by creating and destroying virtual machines on demand.  Node Manager currently supports Amazon Web Services (AWS), Google Cloud Platform (GCP) and Microsoft Azure.
 
-Note: node manager is only required for elastic computing cloud environments.  Fixed size clusters do not require node manager.
+Note: node manager is only required for elastic computing cloud environments.  Fixed size clusters (such as on-premise HPC) do not require node manager.
 
 h2. Install
 
@@ -113,6 +113,15 @@ boot_fail_after = 1800
 # an Arvados node that hasn't been updated for this long.
 node_stale_after = 14400
 
+# Number of consecutive times a node must report as "idle" before it
+# will be considered eligible for shutdown.  Node status is checked
+# each poll period, and node can go idle at any point during a poll
+# period (meaning a node could be reported as idle that has only been
+# idle for 1 second).  With a 60 second poll period, three consecutive
+# status updates of "idle" suggests the node has been idle at least
+# 121 seconds.
+consecutive_idle_count = 3
+
 # Scaling factor to be applied to nodes' available RAM size. Usually there's a
 # variable discrepancy between the advertised RAM value on cloud nodes and the
 # actual amount available.
@@ -282,6 +291,15 @@ poll_stale_after = 600
 # an Arvados node that hasn't been updated for this long.
 node_stale_after = 14400
 
+# Number of consecutive times a node must report as "idle" before it
+# will be considered eligible for shutdown.  Node status is checked
+# each poll period, and node can go idle at any point during a poll
+# period (meaning a node could be reported as idle that has only been
+# idle for 1 second).  With a 60 second poll period, three consecutive
+# status updates of "idle" suggests the node has been idle at least
+# 121 seconds.
+consecutive_idle_count = 3
+
 # Scaling factor to be applied to nodes' available RAM size. Usually there's a
 # variable discrepancy between the advertised RAM value on cloud nodes and the
 # actual amount available.
@@ -470,6 +488,15 @@ boot_fail_after = 1800
 # an Arvados node that hasn't been updated for this long.
 node_stale_after = 14400
 
+# Number of consecutive times a node must report as "idle" before it
+# will be considered eligible for shutdown.  Node status is checked
+# each poll period, and node can go idle at any point during a poll
+# period (meaning a node could be reported as idle that has only been
+# idle for 1 second).  With a 60 second poll period, three consecutive
+# status updates of "idle" suggests the node has been idle at least
+# 121 seconds.
+consecutive_idle_count = 3
+
 # Scaling factor to be applied to nodes' available RAM size. Usually there's a
 # variable discrepancy between the advertised RAM value on cloud nodes and the
 # actual amount available.